Por favor, use este identificador para citar o enlazar este ítem: http://dspace.espoch.edu.ec/handle/123456789/5743
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorAndueza, Félix-
dc.contributor.authorPérez Montalvo, Gabriela Marina-
dc.date.accessioned2017-01-16T16:56:12Z-
dc.date.available2017-01-16T16:56:12Z-
dc.date.issued2016-04-
dc.identifier.citationPérez Montalvo, Gabriela Marina. (2016). Evaluación microbiológica del aire y las superficies de las áreas de quirófanos del Hospital del Instituto Ecuatoriano de Seguridad Social de Riobamba. Escuela Superior Politécnica de Chimborazo. Riobamba.es_ES
dc.identifier.urihttp://dspace.espoch.edu.ec/handle/123456789/5743-
dc.descriptionLos establecimientos de salud son entornos en los que se congregan personas que en mayor o menor grado presentan problemas con su salud. En este contexto el ambiente hospitalario resulta un espacio en el cual se pueden contraer infecciones nosocomiales con el consiguiente deterioro del cuadro clínico preexistente. En el presente estudio se realizaron evaluaciones en ambientes hospitalarios de un Hospital público ubicado en la ciudad de Riobamba, Ecuador tomando en cuenta las áreas más vulnerables como son los quirófanos. Para la recolección de muestras de superficies se utilizó el Método del hisopado, mientras que para las muestras de aire se utilizó el Método de sedimentación o de placa abierta, para procesar las muestras se las incubó de 24 a 48 horas a 37 °C. Para la identificación de los microorganismos encontrados se utilizó pruebas de identificación microbiológicas primarias como oxidasa, catalasa y coloración Gram, conjuntamente se utilizaron kits de identificación microbiana Microgen TM GN ID A+B. En los 4 quirófanos evaluados se obtuvo un total de 0.68, 1.04, 0.23, 0.58 UFC/cm2 para cada quirófano, obteniendo valores menores a los expuestos en la norma UNE EN ISO 14698, mientras que en la evaluación del aire, los quirófanos estarían en la categoría de ambientes muy limpios establecidos por la norma UNE-EN ISO 14644 -1: 2000 que indica que debe poseer < 10 UFC / cm3 de aire para pertenecer a dicha clasificación. Los microorganismos identificados con mayor frecuencia fueron: Escherichia coli, Hafnia alvei, Citrobacter freundii, Burkholderia pseudomallei.es_ES
dc.description.abstractHealth facilities are environments where people greater or lesser degree have problems with their health congregate. In this context the environment hospital is a space in which they can get nosocomial infections with the consequent deterioration of existing clinical picture. In the present study evaluations in hospital environments of a public hospital at Riobamba city, Ecuador taking into account the most vulnerable areas such as surgery rooms were made the method swab was used, whereas for air samples sedimentation Method or open plate was used to process the samples were the incubated for 24 to 48 hours at 37 °C. for collecting surface samples for identifying microorganisms found microbiological identification tests as primary oxidase, catalase and Gram staining was used together microbial identification kits Microgen TM GN ID A+B In 4 surgery rooms evaluated 0.68,1.04,0.23,0.58 CFU/cm2 was obtained for each operating room, getting less than the values reported in the UNE EN ISO 14698, while in the air evaluation, surgery rooms would be in the category of very clean environments established by the UNE-EN ISO 14644-1:2000 indicating that must have <10 CFU/cm3 of air to belong to this classification. The most frequently identified microorganisms were Escherichia coli, hafnia alvei, Citrobacter freundi, Burkholderia pseudomallei.es_ES
dc.language.isospaes_ES
dc.publisherEscuela Superior Politécnica de Chimborazoes_ES
dc.relation.ispartofseriesUDCTFC;56T00661-
dc.subjectAMBIENTE HOSPITALARIOes_ES
dc.subjectQUIRÓFANOSes_ES
dc.subjectINFECCIONES NOSOCOMIALES (PATOLOGÍA)es_ES
dc.subjectMÉTODO DEL HISOPADOes_ES
dc.subjectMÉTODO DE SEDIMENTACIÓNes_ES
dc.subjectIDENTIFICACIÓN MICROBIANAes_ES
dc.subjectBIOQUÍMICAes_ES
dc.titleEvaluación microbiológica del aire y las superficies de las áreas de quirófanos del Hospital del Instituto Ecuatoriano de Seguridad Social de Riobamba.es_ES
dc.typebachelorThesises_ES
dc.contributor.miembrotribunalEscobar, Sandra Noemí-
dc.contributor.miembrotribunalMedina, Gerardo-
Aparece en las colecciones: Bioquímico/a y Farmacéutico/a

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
56T00661.pdf1,35 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.